Item Infomation

Full metadata record
DC FieldValueLanguage
dc.contributor.authorZhao, Feng
dc.date.accessioned2020-02-18T02:29:07Z-
dc.date.available2020-02-18T02:29:07Z-
dc.date.issued2015
dc.identifier.citationRemote SensingVol.7 (2015), Issue 10, pp.14179-14199
dc.identifier.urihttp://tailieuso.tlu.edu.vn/handle/DHTL/4915-
dc.description.abstractIn this study, backward and forward fluorescence radiance within the emission spectrum of 640–850 nm were measured for leaves of soybean, cotton, peanut and wheat using a hyperspectral spectroradiometer coupled with an integration sphere. Fluorescence parameters of crop leaves were retrieved from the leaf hyperspectral measurements by inverting the FluorMODleaf model, a leaf-level fluorescence model able to simulate chlorophyll fluorescence spectra for both sides of leaves. This model is based on the widely used and validated PROSPECT (leaf optical properties) model. Firstly, a sensitivity analysis of the FluorMODleaf model was performed to identify and quantify influential parameters to assist the strategy for the inversion. Implementation of the Extended Fourier Amplitude Sensitivity Test (EFAST) method showed that the leaf chlorophyll content and the fluorescence lifetimes of photosystem I (PSI) and photosystem II (PSII) were the most sensitive parameters among all eight inputs of the FluorMODleaf model. Based on results of sensitivity analysis, the FluorMODleaf model was inverted using the leaf fluorescence spectra measured from both sides of crop leaves. In order to achieve stable inversion results, the Bayesian inference theory was applied. The relative absorption cross section of PSI and PSII and the fluorescence lifetimes of PSI and PSII of the FluorMODleaf model were retrieved with the Bayesian inversion approach. Results showed that the coefficient of determination (R2) and root mean square error (RMSE) between the fluorescence signal reconstructed from the inverted fluorescence parameters and measured in the experiment were 0.96 and 3.14 × 10−6 W·m−2·sr−1·nm−1, respectively, for backward fluorescence, and 0.92 and 3.84 × 10−6 W·m−2·sr−1·nm−1 for forward fluorescence. Based on results, the inverted values of the fluorescence parameters were analyzed, and the potential of this method was investigated.
dc.description.urihttp://www.mdpi.com/2072-4292/7/10/14179
dc.languageeng
dc.subjectRadiative transfer
dc.subjectHyperspectral remote sensing
dc.subjectBayesian approach
dc.subjectModel inversion
dc.subjectFluorMODleaf
dc.subjectChlorophyll fluorescence
dc.titleQuantitative Estimation of Fluorescence Parameters for Crop Leaves with Bayesian Inversion
dc.typeBB
dc.date.update20181114111437.0
dc.date.submitte130605s2015
Appears in Collections:Tài liệu mở

Files in This Item:
There are no files associated with this item.

Bạn đọc là cán bộ, giáo viên, sinh viên của Trường Đại học Thuỷ Lợi cần đăng nhập để Xem trực tuyến/Tải về



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.