Item Infomation


Title: Pressure Correction in the Calibration of Heat Dissipation Sensors
Participants: Zhang, Z.F.
Dai, G.L.
Issue Date: 2019
Series/Report no.: Vadose Zone Journal, Volume 18, Issue 1 (2019), pp.1-5
Abstract: Heat dissipation sensors (HDSs) infer soil matric potential based on the measured rate of temperature rise from a heat source. The process for calibrating these sensors may use a pressure plate apparatus (PPA) to remove water to a certain calibration point that is controlled by pressure. Conventionally, the pressure within the PPA is released before the temperature change calibration points are measured (ΔT0). This conventional HDS calibration approach can take several weeks. We propose that the equilibrated temperature change at pressure (ΔTp) can be corrected empirically to the value at zero pressure. Based on measurements of 14 HDSs between 0.02 and 0.1 MPa, ΔTp was on average 6.2% larger than ΔT0. After pressure correction, using an empirical equation, the difference between the corrected ΔTp and ΔT0 was only 0.28%. These results demonstrate that this empirical approach provides sufficient accuracy to achieve HDS calibration without performing a PPA pressure release.
URI: http://tailieuso.tlu.edu.vn/handle/DHTL/9910
Source: https://acsess.onlinelibrary.wiley.com/doi/10.2136/vzj2019.05.0052
ISSN: 1539-1663
Appears in Collections:Tài liệu mở
ABSTRACTS VIEWS

18

VIEWS & DOWNLOAD

0

Files in This Item:
There are no files associated with this item.

Bạn đọc là cán bộ, giáo viên, sinh viên của Trường Đại học Thuỷ Lợi cần đăng nhập để Xem trực tuyến/Tải về



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.